SBDIS=0, FILDIS=0
SYNFP Operation Setting Register
TCYC | PTP Message Transmission Interval SettingThese bits are used to set the time from the completion of one transmission to the start of the next in cycles of the transmission clock. A value n in these bits means that a transmission interval of n cycles will be secured.No interval is secured if the setting is 00h.We recommend the setting 28h (40 cycles). |
SBDIS | Sync Message Transmission Bandwidth Securing Disable 0 (0): Securing of the bandwidth for the transmission of SYNC messages is enabled (transfer by the EDMAC is given lower priority). 1 (1): Securing of the bandwidth for the transmission of SYNC messages is disabled (transfer by the EDMAC is given higher priority). |
FILDIS | Receive Message domainNumber Filter Disable 0 (0): Filtering conditions for the reception of PTP messages include comparison with the domainNumber field. 1 (1): Filtering conditions for the reception of PTP messages do not include comparison with the domainNumber field. |